ECP-2001 is a universal process panel meter / controller with a host features from a single meter.

It is progammable for Current, Voltage, Temperature and Transducer inputs, Serial Communication RS-485 and has four output Alarms each with 7 recipe menus.

It also features a bi-colour LED display Red / Green which may also be progammed to change colour Red / Green, Green / Red in alarm condition.

The display is fully scaleable across the range - 999 to +99999.

The panel meter as a

Credit Cards

Eagle Controls - Large Digit Displays

Strain Gauge / Loadcell Panel Meter

4 Alarm Outputs Standard, RS-485 Serial Communications Input/Output Standard, Analogue Output Option

MODEL ECP 2001 - Strain Gauge / Loadcell Panel Meter A competitively priced, fully programmable Strain Gauge / Loadcell panel meter suitable for Loadcells with a typical sensitivity of 2mv/V and for high sensitivity applications. It features a fully scaleable 5 digit bi-colour LED display across the range -9999 to +99999. 4 alarm output options are fitted as standard where the display changes colour in the alarm condition if programmed to do so. Analogue output via an external isolator is an option (consult sales office) and serial communications RS-485 input and output is fitted as standard.

Excitation

For high accuracy (6 wire) and Intrinsically Safe applications use a BASEEFA Certified isolator, consult sales office.

Display Colour Selection

The display may be programmed to be

Standard features

4 Alarm Outputs

4 alarm outputs are available via N/O 3 A relays. The alarms are fully scaleable and independent of one another and may be set for HI or LO trip. The alarms can be programmed to energise or de-energise in the alarm state, open / close or latch and have independent variable hysteresis, time delay trip response adjustable 0-250 seconds. In the alarm state the display will change colour if programmed to do so.

Serial Input / Output (fitted as standard)

Up to 31 units may be multi-dropped. The displayed value can be uploaded or downloaded from a PC via an RS-485 port. One unit can also be programmed as a 'master' with the remaining multi-dropped units acting as 'slaves'.

Analogue Output Option

Isolated 4-20mA or 0-10V, for an assigned zero and span can be supplied as an output option.

Technical Specification
Description Data
Display 5 digit seven segment LED 14.2mm high
Display changes colour in alarm state
A to D Converter Accuracy +/- 0.02% of range
Communications RS-485
Alarm output 4 N/0 3A relay @ 250Vac
Analogue output External Isolator 4-20mA, 0-10V
Scaling/Calibration Decimal point in resistance mode
Accuracy < +/- 0.005% (+/- 1 digit)
Input bias current < 0. 1 micro amps
Zero drift (0-50C) +/- 0.0025% / C of range +/- 1 digit
Span drift (0-50C) +/- 0.01% / C of reading +/- 1 digit
Ripple rejection < 2 digits with 1/4 mV PK to PK ripple @ 50/60 hz
Step Response 2 secs to 95% of final value
Power Supply 85-265Vac or 18-30 Vac/dc < 5VA consumption
Environmental Operating temperature 0-50 C Storage -40 to + 85 C
Case size H x 48, W x 96, D x 132mm including connectors
Panel cutout 91 x 44.5mm

Anything we can tell you about our Large Digit Strain / Load cell Input Displays:
Tel: 01462 670566 or Email: info@eaglecontrols.co.uk